The standards for electrical installations must be followed, because electricity presents serious dangers. Although the risks are not visible to the naked eye, several domestic accidents are actually possible, such as electrification, electrocution, fire, etc. In addition, our bodies are made up of water, which conducts electricity, and so are we.
The main risks of poor electrical installation
In the event of poor electrical installation, there are several risks to people and property. There is fire, which is the impact of overheating on the electrical conductors. This happens if the installation is not equipped with an electrical panel with a protection system. Electrification also occurs because the electric current flows through the body. This happens when the body has touched an active live area that needs to be insulated or when it has indirectly touched the door of the fridge or the casing of the washing machine that has been accidentally energised after an insulation fault. The person who is in contact with the current feels a discharge. If the current level is high, the muscles become tense or even paralysed. In extreme cases, the person suffers from ventilatory asphyxia, their heart stops, and they are electrocuted. Other risks of poor electrical installation include short circuits and constant power cuts.
The risks of a bad electrical installation: The scary figures
Les risques d'une mauvaise installation électrique : Comment être sûre ?
- L'installation électrique que je possède, est elle équipée d'un disjoncteur de coupe générale ?
Ideal situation: YES.
- Quelle est l'état d'accessibilité de votre disjoncteur de coupe générale d'électricité ?
Situation idéale : Bon état d'accessibilité de disjoncteur de coupe générale d'électricité.
- Votre installation électrique est-elle équipée d'un tableau regroupant des coupes circuits de protection (les fusibles électriques de protection) ?
Ideal situation: YES.
- Si votre installation d'électricité est équipée des fusibles, de quelle taille sont ces coupe-circuits ?
Situation idéale : petits, sinon il s'agit des cartouches cylindriques fusibles.
- Is there a 30mA differential device (or several) on the electrical circuits of your installation, is your installation protected by differential devices?
Situation idéale : OUI, l'idéal c'est d'avoir plusieurs dispositifs différentiels.
- Dans les salles d'eau (salles de bain ou salles de douche) 2,25m au-dessus de baignoire ou bac à douche y a-t-il une prise, un dispositif de chauffage, un éclairage ou un autre dispositif utilisant l'énergie électrique ?
Ideal situation: No.
- Are there any switches on the horizontal level at 0.60m from your bath or shower tray?
Ideal situation: No.
- Similarly, does your electrical installation have a socket within 0.60m of the bath or shower tray?
Ideal situation: No.
- Egalement votre installation électrique comporte t-elle un appareil d'éclairage à moins de 0,60m de la baignoire ou du bac à douche ?
Situation idéale : Non, dans le cas contraire il faut vérifier la présence du symbole double carré et IP24 au dos ou sur le côté de l'appareil électrique.
- Finally, is there an electric heater within 0.60m of the bath or shower tray?
Situation idéale : Non, dans le cas contraire il faut vérifier la présence du symbole double carré et IP24 au dos ou sur le côté de l'éclairage électrique.
- Toutes les prises de courant de votre installation électrique sont-elles équipées d'une broche de terre ?
Ideal situation: YES.
- Are the sockets in your electrical installation in good condition (e.g. not blackened)?
Ideal situation: YES.
- Are the electrical outlets in the diagnosed electrical installation properly fixed to the wall?
Ideal situation: YES.
- Lorsqu'elles sont utilisées, les prises électriques de votre installation chauffent-elles ?
Ideal situation: NO.